Complete This Table For Refrigerant-134A

Saturated Refrigerant 134a Temperature Table Decoration Jacques Garcia

Complete This Table For Refrigerant-134A. R134a has a global warming potential (gwp) of 1300 with respect to carbon dioxide. Web complete the following table for refrigerant 134a ( 16 marks).

Saturated Refrigerant 134a Temperature Table Decoration Jacques Garcia
Saturated Refrigerant 134a Temperature Table Decoration Jacques Garcia

Note the reading of compressor water, mechanical device outlet condenser outlet, evaporator temperature pressure & of varied parameters within the setup. Web table reading taken from the process of r134a refrigerant placed within the experimental setup. R134a has a global warming potential (gwp) of 1300 with respect to carbon dioxide. Use data from the steam tables. State 1:t = 10 °c, p = 300 kpa , from table a 12 (saturated refrigerant 134a pressure table), for p = 280 kpa, tsat = 1.25 °c, for p = 320 kpa, tsat = 2.46 °c, hence, for p = 300 kpa, tsat = This is the normal domestic refrigerator having refrigerant 180 grams placed in the system. There is currently serious consideration of replacing it with r744 (carbon dioxide) in refrigeration and heat pump applications. Web complete the following table for refrigerant 134a ( 16 marks). You'll get a detailed solution from a subject matter expert that helps you learn core concepts. State 1:t = 8 °c, p = 320 kpa , from table a 12 (saturated refrigerant 134a pressure table), for p = 320 kpa, tsat = 2.46 °c, as t < tsat , hence, state 1 is compressed (subcooled) liquid, hence, conditions are nearly the same as those at saturated liquid corresponding to t = 8 °c.

R134a has a global warming potential (gwp) of 1300 with respect to carbon dioxide. Web table reading taken from the process of r134a refrigerant placed within the experimental setup. You'll get a detailed solution from a subject matter expert that helps you learn core concepts. Use data from the steam tables. State 1:t = 8 °c, p = 320 kpa , from table a 12 (saturated refrigerant 134a pressure table), for p = 320 kpa, tsat = 2.46 °c, as t < tsat , hence, state 1 is compressed (subcooled) liquid, hence, conditions are nearly the same as those at saturated liquid corresponding to t = 8 °c. State 1:t = 10 °c, p = 300 kpa , from table a 12 (saturated refrigerant 134a pressure table), for p = 280 kpa, tsat = 1.25 °c, for p = 320 kpa, tsat = 2.46 °c, hence, for p = 300 kpa, tsat = Note the reading of compressor water, mechanical device outlet condenser outlet, evaporator temperature pressure & of varied parameters within the setup. R134a has a global warming potential (gwp) of 1300 with respect to carbon dioxide. Web complete the following table for refrigerant 134a ( 16 marks). Use data from the steam tables. Т, °f p, psia phase description h, btu/lbm х 80 78 15 0.6 10 70 180 129.46 110 1.0 this problem has been solved!